1 because of the two bending mode, the loss of long time, resulting in pressure foot after the product size is out of spec phenomenon.
2 die checklist, every two Monday times, by the technician inspection, Captain confirm.
3 before the "E2" size and planeness bad, mold repair, affect the size of A is beyond the specifications, our staff will focus on "E2" peaceful face, and ignore the A size, A size caused by bad output.
4 client products, customers to help try, try to use OK.
5 I treasurer storage products, at present not rework, in does not affect the customers, please customers receive.
6.10 months, 9 days manager Zhang, already dies on the loss in October 20th is expected to repair, repair.
7.. Will this size in the first piece inspection, every day before starting a 5pcs product, the size measurement, confirm the OK, can produce.
8.. Presser foot station operator every half hour a self-test, each taking 5pcs products of this size are confirmed.
9..IPQC daily inspection four times, each time 5pcs extraction products of this size measurement confirmation.
10 now for mould repair.