If an earthing switch is present within the generator circuit breaker cubicle or between the generator and the circuit breaker then interlock circuits (electrical and/or mechanical)should be present to prevent operation of the earthing switch when the generator is turning above turning gear speed or voltage is present.
如果接地开关是在发电机断路器柜或发电机和断路器之间,当发电机转动齿轮的超速或电压出现时,应由互锁电路(电气和/或机械)防止接地开关的操作
我觉得这样翻译“当发电机转动齿轮的超速或电压出现时”,好像不对
人气:138 ℃ 时间:2020-04-09 04:15:39
解答
如果接地开关是在发电机断路器柜里面或是在发电机和断路器之间, 当发电机转动齿轮超速或存在电压时,应由互锁电路(电气和/或机械)来防止接地开关的操作.